Perpustakaan STIKes Mitra Keluarga

  • Beranda
  • Informasi
  • Berita
  • Bantuan
  • Masuk
  • Area Anggota
  • Pilih Bahasa :
    Bahasa Arab Bahasa Bengal Bahasa Brazil Portugis Bahasa Inggris Bahasa Spanyol Bahasa Jerman Bahasa Indonesia Bahasa Jepang Bahasa Melayu Bahasa Persia Bahasa Rusia Bahasa Thailand Bahasa Turki Bahasa Urdu

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Image of PENGUJIAN SENSITIVITAS DAN SPESIFISITAS PADA METODE MINIATURIZED MOST PROBABLE NUMBER (mMPN) TERHADAP METODE ANGKA LEMPENG TOTAL (ALT)

REPOSITORI KTI/Skripsi/KIAN

PENGUJIAN SENSITIVITAS DAN SPESIFISITAS PADA METODE MINIATURIZED MOST PROBABLE NUMBER (mMPN) TERHADAP METODE ANGKA LEMPENG TOTAL (ALT)

Sarsya Mardliyah - Nama Orang;

ABSTRACT

Contaminated and consumed water can be the main cause of foodborne diseases. Therefore,
water needs to be examined bacteriologically as a water quality test. Each examination
method needs to be tested for the validity of the method, such as testing sensitivity and
specificity. This research aims to determine the sensitivity and specificity values of the
miniaturized Most Probable Number method against the Total Plate Number method. This
type of research is quantitative with a pre-experimental research design. The samples used
were bottled drinking water, refillable drinking water, and iced drinks sold around the
Pengasinan area. The samples used in this research were 28 samples, namely 13 positive
samples and 15 negative samples. The data analysis used was the Cohen's Kappa test. The
results were obtained based on the Cohen's Kappa statistical test with a sample of 28. The
mMPN kit was found to have a sensitivity value of 84.6% and a specificity value of 100%.
Bacteriological test results showed that 10 out of 12 samples (83.33%) of iced tea samples
were contaminated with bacterial counts >100 CFU/ml, 3 out of 7 samples (42.85%) of refill
drinking water samples were contaminated with bacterial counts >100 CFU/ml. ml, and 6
samples (100%) of bottled drinking water were not contaminated with bacterial counts


Ketersediaan
KTI1498Q1D3.TLM 1498 2024RAK REFERENSI TUGAS AKHIRTersedia namun tidak untuk dipinjamkan - TIDAK DAPAT DIPINJAMKAN
Informasi Detail
Judul Seri
-
No. Panggil
D3.TLM 1498 2024
Penerbit
Bekasi : Prodi Tekno. Lab. Medis STIKes Mitra Keluarga., 2024
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
D3.TLM 1498 2024
Tipe Isi
Text
Tipe Media
Tercetak
Tipe Pembawa
-
Edisi
-
Subjek
MINIATURIZED MOST PROBABLE NUMBER (mMPN)
Info Detail Spesifik
-
Pernyataan Tanggungjawab
Sarsya Mardliyah
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • “PENGUJIAN SENSITIVITAS DAN SPESIFISITAS PADA METODE MINIATURIZED MOST PROBABLE NUMBER (mMPN) TERHADAP METODE ANGKA LEMPENG TOTAL (ALT)”
    Pembimbing : Noor Andryan Ilsan, Ph.D,
  • ABSTRAK
Komentar

Anda harus masuk sebelum memberikan komentar

Perpustakaan STIKes Mitra Keluarga
  • Informasi
  • Kubuku
  • Link E-Resource
  • Repository

Tentang Kami

Perpustakaan STIKes Mitra Keluarga menerapkan Sistem Layanan Terbuka bagi pengunjung, dalam hal ini pengunjung dapat langsung mencari koleksi yang diinginkannya ke rak yang tersedia.


Statistik Pengujung

Hari ini : 1 Minggu Terakhir : 1 Bulan Terakhir : Seluruh :

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik